The Standard Tank Configuration
The standard tank configuration is a useful reference standard for mixing process design. It provides adequate mixing for most processing requirements found in industry. However, it should be stressed that the Standard Tank Configuration is an arbitrary standard which in some circumstances is not the best configuration to use. For special processing conditions, such as mixing liquids with a high solids content, a high viscosity or a shear sensitive character, this configuration may be impractical.
The Standard Tank Configuration has the following geometrical relationships:
THE AGITATOR |
A standard 6 blade flat blade turbine impeller | |
IMPELLER DIAMETER |
Di | = 1/3 tank diameter Dt |
IMPELLER HEIGHT FROM TANK BOTTOM |
Hi |
= 1.0
impeller diameter Di |
IMPELLER BLADE WIDTH |
q | = 1/5 impeller diameter Di |
IMPELLER BLADE LENGTH |
r | = 1/4 impeller diameter Di |
LIQUID HEIGHT |
Ht | = 1.0 tank diameter Dt |
BAFFLE NUMBER |
Quantity | = 4, vertically mounted at the tank wall and extending from the tank bottom to above the liquid surface |
BAFFLE WIDTH |
Wb | = 1/10 tank diameter Dt |